R290 heat pumps and the F-gas rules
From 1 January 2027, the EU's F-gas rules ban monobloc heat pumps and split air to water systems of 12 kW or less that use a fluorinated refrigerant with a global warming potential of 150 or more, unless safety requirements need one. SEAI recommends heat pumps with refrigerants that are not fluorinated, such as hydrocarbons like propane, R290.
What changes from 2027 for heat pumps of 12 kW or less, why SEAI recommends refrigerants without fluorine, and what propane needs.
Free and no obligation. Your request goes to one installer in your county, not a list.
- 12 kWor less: the size the dates cover
- 150the GWP limit from 2027
- 2032monobloc: no fluorinated gas
- 2035split: no fluorinated gas

The dates
- 1 January 2027. The ban starts for monobloc heat pumps of 12 kW or less, and split air to water systems of 12 kW or less, that use a fluorinated refrigerant of GWP 150 or more.
- 1 January 2032. It widens to monobloc heat pumps of 12 kW or less that contain any fluorinated gas.
- 1 January 2035. And to split systems of 12 kW or less that contain or rely on fluorinated gases.
Each ban has an exception where safety requirements need a fluorinated gas. They are in Regulation (EU) 2024/573, the EU F-gas Regulation.
Monobloc and split
Monobloc
- SEAI's description
- Factory-charged, with the whole refrigerant circuit sealed inside its casing
- GWP 150 or more banned from
- 1 January 2027
- Fluorinated gas banned from
- 1 January 2032
Split
- SEAI's description
- One outdoor and one indoor unit linked by refrigerant piping
- GWP 150 or more banned from
- 1 January 2027
- Fluorinated gas banned from
- 1 January 2035
Price your heat pump
Three taps and the price and the grant show as you go. Your name and number come last, and only if you want an installer to price it.
A semi-detached house, heated by oil now, built before 2007: €12,500 to €18,200, SEAI grant up to €12,500.
How the price is worked out
For a house the price is the range Irish sellers charge to supply and fit an air to water heat pump system, before the grant: €12,500 to €18,200. Prices that state VAT include it. For an apartment it is SEAI's median cost, €9,025. The grant is SEAI's: up to €12,500 for a house and €9,500 for an apartment where oil, gas, solid fuel or storage heaters are replaced, up to €6,500 (€4,500 in an apartment) for a replacement heat pump, and none for a home built and occupied in 2021 or later. Radiator work, the cylinder and an electricity supply upgrade vary with the house. Use it to plan with. It isn't a quote: an installer prices yours after a survey.
R290, propane
R290 is propane used as a refrigerant. SEAI recommends heat pumps with refrigerants that are not fluorinated, such as hydrocarbons, and propane is one.
Propane is highly flammable. If the refrigerant leaked, a flammable atmosphere could form for a short time, so the unit has a protective zone around it with the precautions its manual sets. Typically that means keeping a minimum distance from windows and doors, pavements and neighbouring properties.
Who works on it
- An F-gas certified engineer. SEAI's standards need one to install the heat pump, check it for leaks and commission it.
- The F-gas company certificate. Part of the handover papers, confirming the installation, the leak checks and the commissioning.
- Leak checks on synthetic refrigerants. A heat pump with an HFC or HFO refrigerant above certain sizes has mandatory leak checks under the F-gas rules.
On the quote
- The refrigerant. Named, with its GWP.
- Monobloc or split. Which one it is.
- The protective zone. For an R290 unit, where it falls, marked on the plan with the unit's position.
Other pages on your home and system
Air to water heat pumpsWhat the system is and what it heats: radiators, floors and the cylinder. €12,500 to €18,200 fitted in a house.
Detached houses and bungalowsSEAI's median cost for a detached house was €17,000, before a grant of up to €12,500.
Semi-detached housesA median of €16,741 with the end of terrace, so about €4,241 once the full grant comes off.
Terraced housesA median of €16,000. The outdoor unit can now go on the front wall, within limits.
ApartmentsSEAI pays up to €9,500 for an apartment. Its median cost was €9,025.
Radiators and underfloor heatingUp to €2,000 of the grant goes on them where the design calls for it.Questions before you buy
What is an R290 heat pump?
A heat pump that uses propane as its refrigerant. SEAI recommends refrigerants that are not fluorinated, such as hydrocarbons.
Are F-gas heat pumps being banned?
From 1 January 2027, monobloc and split air to water heat pumps of 12 kW or less cannot use a fluorinated refrigerant with a GWP of 150 or more, unless safety requirements need one. Monobloc units must be free of fluorinated gas from 1 January 2032 and split units from 1 January 2035.
What does R290 need around it?
A protective zone, because propane is highly flammable. The unit's manual sets the precautions, typically a minimum distance from windows, doors, pavements and neighbouring properties.
Who can install an R290 heat pump?
SEAI's standards need an F-gas certified engineer to install, leak check and commission a heat pump.
What does GWP mean?
Global warming potential: how strongly a gas warms the climate compared with carbon dioxide. The EU limit for heat pumps of 12 kW or less from 1 January 2027 is 150.
Everything on this site
Your home and the system
Costs, grants and paying

See the price and the grant before anyone rings
Pick the home, what heats it now and when it was built. When you want a firm price, it goes to a single heat pump installer in your county.
