Technical assessment and heat loss

A home built before 2007 needs a technical assessment before the grant application, unless a valid BER already shows a heat loss indicator of 2.3 W/K·m² or less. SEAI pays €200 toward it. A home built from 2007 on can send a self-declaration form instead. The heat loss indicator is the home's fabric and ventilation heat loss divided by its floor area.

Who needs the assessment, what the heat loss indicator measures and what happens when a house falls short of it.

Free and no obligation. Your request goes to one installer in your county, not a list.

  • 2.3 W/K·m²the heat loss the grant needs
  • €200SEAI grant toward the assessment
  • before 2007built: the assessment is required
  • €50BER grant after the work
Insulation laid between the timber joists in an attic

What the heat loss indicator measures

The heat loss indicator, HLI, adds up the heat a home loses through its walls, roof, floor, windows and doors and the heat it loses to ventilation, then divides that by the floor area. The unit is watts for each degree between inside and outside, for each square metre of floor: W/K·m².

The energy rating method, DEAP, works it out from a BER of the home. A lower figure means a house that holds its heat better. On individual grants, a heat pump needs 2.3 or less before the grant is paid.

Who needs the assessment

Built before 2007

The technical assessment
Required before you apply, unless a valid BER shows an HLI of 2.3 or less
Insulation it names
Has to be done for the heat pump grant
The self-declaration form
Only with a valid BER that already shows 2.3 or less
SEAI grant toward it
€200

Built from 2007 on

The technical assessment
Optional
Insulation it names
Not required
The self-declaration form
Sent instead of the assessment
SEAI grant toward it
€200

Price your heat pump

Three taps and the price and the grant show as you go. Your name and number come last, and only if you want an installer to price it.

A semi-detached house, heated by oil now, built before 2007: €12,500 to €18,200, SEAI grant up to €12,500.

Step 1 of 5

What kind of home is it?

Pick the closest. The installer asks the rest.

How the price is worked out

For a house the price is the range Irish sellers charge to supply and fit an air to water heat pump system, before the grant: €12,500 to €18,200. Prices that state VAT include it. For an apartment it is SEAI's median cost, €9,025. The grant is SEAI's: up to €12,500 for a house and €9,500 for an apartment where oil, gas, solid fuel or storage heaters are replaced, up to €6,500 (€4,500 in an apartment) for a replacement heat pump, and none for a home built and occupied in 2021 or later. Radiator work, the cylinder and an electricity supply upgrade vary with the house. Use it to plan with. It isn't a quote: an installer prices yours after a survey.

What the assessment involves

  1. A registered BER assessor. Technical advisors have to be registered domestic BER assessors.
  2. A BER of the home as it is. The assessment is based on a published BER that reflects the home at the time.
  3. The heat loss figure. Worked out in DEAP from that BER.
  4. Options if it falls short. The advisor sets out insulation and airtightness options with the pros and cons of each, for example external wall insulation against roof insulation and new windows.
  5. The form. No fee is payable to SEAI for submitting it.

What it costs

The assessment

agreed with the advisor

The advisor gives a quotation with VAT before starting. SEAI pays €200 toward it.

A BER after the work

€280

SEAI's median for a semi-detached house. The grant pays €50 toward it.

Insulation the assessment names

priced on the survey

In a home built before 2007 it comes before the heat pump.

Through a One Stop Shop

Since July 2026, SEAI no longer applies the 2.3 limit to a heat pump fitted as part of a whole house upgrade through these programmes: One Stop Shop, Community Energy Grant and Warmer Homes Scheme (Warmer Homes only when its team advises). On individual grants the limit still has to be met before the grant is paid. One Stop Shop or individual grants.

Questions before you buy

What is a heat loss indicator?

The fabric and ventilation heat loss of a home divided by its floor area, in W/K·m². The heat pump grant needs 2.3 or less on individual grants.

Do I need a technical assessment for the heat pump grant?

A home built before 2007 needs a technical assessment before the grant application, unless a valid BER already shows a heat loss indicator of 2.3 W/K·m² or less. SEAI pays €200 toward it. A home built from 2007 on can send a self-declaration form instead.

How much does a technical assessment cost?

The fee is agreed between you and the technical advisor, who gives a quotation with VAT first. SEAI's grant toward it is €200.

Who can do a technical assessment?

A technical advisor who is a registered domestic BER assessor.

What if my house fails the heat loss check?

The advisor sets out the insulation and airtightness work that would bring it to 2.3 or less, with the pros and cons of each. In a home built before 2007 that work comes first.

Does the heat loss limit apply through a One Stop Shop?

Not since July 2026, for a heat pump in a whole house upgrade. It still applies to individual grants.

Everything on this site

An air source heat pump on white gravel against a white wall, with shrubs on each side

See the price and the grant before anyone rings

Pick the home, what heats it now and when it was built. When you want a firm price, it goes to a single heat pump installer in your county.